BUZZI UNICEM S.p.A.- Stabilimento di Guidonia 
Punto di Emissione n.11 
Analisi Valori Medi 

  [Mese Precedente]    [Mese Successivo]    [Principale]

 

Mensile lineare 11/2018
 
 
NOx (Come NO2) 
 
 
mg/Nm³
 
SO2 
 
 
mg/Nm³
 
COT (Come C) 
 
 
mgC/Nm³
 
HCl 
 
 
mg/Nm³
 
HF 
 
 
mg/Nm³
 
Polveri 
 
 
mg/Nm³
 
CO 
 
 
mg/Nm³
 
NH3 
 
 
mg/Nm³
 
O2 Secco 
 
 
% v/v
 
Temperatura Camino 
 
 
°C
 
H2O Camino 
 
 
% v/v
 
Portata Fumi Secchi 
 
 
Nm³/h
01/11/2018 400.7 0.018 23.0 0.94 0.05 0.00 217.4 15.20 13.07 94 9.14 397289
02/11/2018 401.5 0.000 24.5 0.88 0.15 0.00 221.7 10.39 13.36 89 8.79 416786
03/11/2018 394.8 0.000 24.3 0.86 0.23 0.00 227.8 9.12 13.36 89 8.69 414924
04/11/2018 392.9 0.000 25.7 0.84 0.33 0.00 393.0 30.07 13.26 88 8.47 414882
05/11/2018 399.0 0.004 30.2 1.01 0.14 0.01 309.1 38.28 12.86 91 9.10 389794
06/11/2018 389.9 0.000 29.8 1.00 0.02 0.00 282.9 13.96 13.13 85 9.15 403448
07/11/2018 402.7 0.000 30.4 1.17 0.07 0.00 272.4 9.85 13.32 86 9.03 409702
08/11/2018 405.3 0.175 28.6 0.98 0.15 0.00 272.7 4.83 13.38 86 8.78 407182
09/11/2018 393.4 3.483 28.8 1.13 0.07 0.00 228.4 15.73 13.17 91 9.02 398089
10/11/2018 393.7 0.000 30.4 1.21 0.09 0.00 246.2 5.06 13.35 85 8.97 409399
11/11/2018 403.6 0.000 28.7 1.22 0.12 0.00 236.6 4.40 13.33 85 8.89 406894
12/11/2018 353.0 0.221 30.4 1.15 0.18 0.00 337.2 29.46 13.17 91 8.87 396784
13/11/2018 399.1 0.001 31.5 1.31 0.10 0.00 251.7 7.90 13.36 85 8.88 405921
14/11/2018 398.1 0.118 33.9 1.41 0.14 0.00 256.7 24.20 12.99 90 8.92 394309
15/11/2018 388.4 0.000 30.1 1.25 0.13 0.00 251.5 1.97 13.52 84 8.86 404140
16/11/2018 393.2 3.781 27.1 1.03 0.18 0.00 254.2 13.84 13.19 90 8.69 392520
17/11/2018 385.9 0.023 25.9 0.79 0.21 0.00 254.2 4.34 13.46 86 7.90 413010
18/11/2018 391.4 0.000 29.9 1.06 0.44 0.00 291.6 7.77 13.38 85 8.10 413276
19/11/2018 391.3 0.006 30.9 0.85 0.49 0.00 352.8 42.08 13.06 86 8.44 401323
20/11/2018 395.7 0.058 23.5 0.62 0.34 0.00 507.8 20.12 13.33 88 8.49 418270
21/11/2018    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A. 74    N.A.    N.A.
22/11/2018    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F. 42    I.F.    I.F.
23/11/2018    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F. 19    I.F.    I.F.
24/11/2018    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F. 17    I.F.    I.F.
25/11/2018    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F. 16    I.F.    I.F.
26/11/2018    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F. 14    I.F.    I.F.
27/11/2018    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F. 12    I.F.    I.F.
28/11/2018    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F. 10    I.F.    I.F.
29/11/2018    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F. 10    I.F.    I.F.
30/11/2018    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F.    I.F. 11    I.F.    I.F.
  
Soglia 450.0 100.000 80.0 10.00 1.00 18.00 - 70.00 - - - 600000
Nr Sup. 0 0 0 0 0 0 - 0 - - - 0
Max 405.3 3.781 33.9 1.41 0.49 0.01 507.8 42.08 13.52 94 9.15 418270
Min 353.0 0.000 23.0 0.62 0.02 0.00 217.4 1.97 12.86 10 7.90 389794
  
 
  
 
NOx (Come NO2) 
 
 
mg/Nm³
 
SO2 
 
 
mg/Nm³
 
COT (Come C) 
 
 
mgC/Nm³
 
HCl 
 
 
mg/Nm³
 
HF 
 
 
mg/Nm³
 
Polveri 
 
 
mg/Nm³
 
CO 
 
 
mg/Nm³
 
NH3 
 
 
mg/Nm³
 
O2 Secco 
 
 
% v/v
 
Temperatura Camino 
 
 
°C
 
H2O Camino 
 
 
% v/v
 
Portata Fumi Secchi 
 
 
Nm³/h
Mese 393.8 0.394 28.4 1.04 0.18 0.00 283.5 15.60 13.25 66 8.76 405364
Soglia - - - - - - - -
Ore valide 482 482 482 482 482 482 482 482 482 720 482 482
Ore N.F. 482 482 482 482 482 482 482 482 482 720 482 482
  

  [Mese Precedente]    [Mese Successivo]    [Principale]


Legenda

Ore N.F.
Ore di Normale Funzionamento
Ore in cui l'impianto è in esercizio al di sopra del minimo tecnico ambientale
*
Non Valido
L'indice di disponibilità dei dati medi orari è inferiore al 70% (ex D.Lgs 152/2006)
N.A.
Non Applicabile
Durante la giornata l'impianto controllato ha superato lo stato di minimo tecnico per una durata inferiore alla mimima richiesta, quindi il valore medio calcolato non è significativo (ex D.Lgs 152/2006). L'impianto controllato, per quanto concerne la media aggregata, è da considerare fermo
I.F.
Impianto Fermo
Durante la giornata l'impianto controllato non ha mai superato lo stato di minimo tecnico.
N.D.
Non Disponibile
Le informazioni per la grandezza non sono disponibili a causa di problemi tecnici del sistema di misurazione o memorizzazione.
F.S.
Fuori Servizio
Le misurazioni non sono state effettuate a causa di guasto o manutenzione delle apparecchiature di misura.
>
Superamento soglia normativa
Il valore medio misurato è superiore al valore massimo ammissibile.

 

 

Buzzi Unicem - Guidonia - 652-0035-97 