Buzzi Unicem S.p.a. - Cementeria di Monselice (PD)
Emissioni Forno Cottura Clinker
Analisi Valori Medi
[Mese Precedente] [Mese Successivo] [Principale]
|
NOx mg/Nm³ |
SO2 mg/Nm³ |
Polveri mg/Nm³ |
CO mg/Nm³ |
COT mg/Nm³ |
HCl mg/Nm³ |
HF mg/Nm³ |
NH3 mg/Nm³ |
Ore Valide n |
Ore Funzionamento n |
||||||||||
Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | |
01/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
02/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
03/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
04/05/2020 | I.F. | 0% | I.F. | 0% | I.F. | 0% | I.F. | 0% | I.F. | 0% | I.F. | 0% | I.F. | 0% | I.F. | 0% | 0 | 0% | 0 | 0% |
05/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
06/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
07/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
08/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
09/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
10/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
11/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
12/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
13/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
14/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
15/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
16/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
17/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
18/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
19/05/2020 | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | I.F. | 100% | 0 | 100% | 0 | 100% |
20/05/2020 | 420.4 | 100% | 0.4 | 100% | 0.1 | 100% | 417.8 | 100% | 27.2 | 100% | 1.1 | 100% | 0.2 | 100% | 24.5 | 100% | 19 | 100% | 19 | 100% |
21/05/2020 | 447.9 | 100% | 0.4 | 100% | 0.0 | 100% | 368.7 | 100% | 25.4 | 100% | 1.0 | 100% | 0.1 | 100% | 3.8 | 100% | 24 | 100% | 24 | 100% |
22/05/2020 | 454.7 | 100% | 0.3 | 100% | 0.0 | 100% | 344.8 | 100% | 23.8 | 100% | 0.6 | 100% | 0.0 | 100% | 8.5 | 100% | 24 | 100% | 24 | 100% |
23/05/2020 | 462.7 | 100% | 0.4 | 100% | 0.0 | 100% | 318.7 | 100% | 22.7 | 100% | 0.6 | 100% | 0.1 | 100% | 0.0 | 100% | 24 | 100% | 24 | 100% |
24/05/2020 | 454.2 | 100% | 0.4 | 100% | 0.0 | 100% | 327.0 | 100% | 21.8 | 100% | 0.4 | 100% | 0.1 | 100% | 0.5 | 100% | 24 | 100% | 24 | 100% |
25/05/2020 | 458.8 | 100% | 0.3 | 100% | 0.0 | 100% | 318.9 | 100% | 21.2 | 100% | 0.8 | 100% | 0.1 | 100% | 11.3 | 100% | 24 | 100% | 24 | 100% |
26/05/2020 | 465.9 | 100% | 0.3 | 100% | 0.0 | 100% | 301.6 | 100% | 20.5 | 100% | 0.8 | 100% | 0.1 | 100% | 7.1 | 100% | 24 | 100% | 24 | 100% |
27/05/2020 | 442.0 | 100% | 0.3 | 100% | 0.0 | 100% | 292.7 | 100% | 19.6 | 100% | 1.0 | 100% | 0.0 | 100% | 4.6 | 100% | 24 | 100% | 24 | 100% |
28/05/2020 | 447.6 | 100% | 0.3 | 100% | 0.0 | 100% | 278.7 | 100% | 19.5 | 100% | 1.2 | 100% | 0.0 | 100% | 9.9 | 100% | 24 | 100% | 24 | 100% |
29/05/2020 | 418.4 | 100% | 0.3 | 100% | 0.0 | 100% | 278.2 | 100% | 19.5 | 100% | 0.9 | 100% | 0.0 | 100% | 3.5 | 100% | 24 | 100% | 24 | 100% |
30/05/2020 | 431.5 | 100% | 0.4 | 100% | 0.0 | 100% | 302.0 | 100% | 20.8 | 100% | 0.7 | 100% | 0.0 | 100% | 0.0 | 100% | 24 | 100% | 24 | 100% |
31/05/2020 | 447.9 | 100% | 0.4 | 100% | 0.0 | 100% | 315.4 | 100% | 21.4 | 100% | 0.6 | 100% | 0.0 | 100% | 0.0 | 100% | 24 | 100% | 24 | 100% |
|
NOx mg/Nm³ |
SO2 mg/Nm³ |
Polveri mg/Nm³ |
CO mg/Nm³ |
COT mg/Nm³ |
HCl mg/Nm³ |
HF mg/Nm³ |
NH3 mg/Nm³ |
Ore Valide n |
Ore Funzionamento n |
||||||||||
Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | Valore | % Disp. | |
Mese | 446.5 | 100% | 0.4 | 100% | 0.0 | 100% | 320.4 | 100% | 21.9 | 100% | 0.8 | 100% | 0.1 | 100% | 5.8 | 100% | 283 | 100% | 283 | 100% |
Soglia | 500.0 | 50.0 | 10.0 | 1500.0 | 50.0 | 10.0 | 1.0 | 250.0 | - | - | ||||||||||
Ore valide | 283 | 283 | 283 | 283 | 283 | 283 | 283 | 283 | - | - | ||||||||||
Ore N.F. | 284 | 284 | 284 | 284 | 284 | 284 | 284 | 284 | - | - | ||||||||||
[Mese Precedente] [Mese Successivo] [Principale]
(NV) |
Non Valido Le misurazioni non sono significative in quanto durante il periodo le apparecchiature od il sistema di misurazione ha dichiarato malfunzionamenti, quindi le misurazioni effettuate non sono attendibili. |
Non Valido La media giornaliera non è valida perchè nel giorno sono state scartate più di tre medie orarie per manutenzione o guasto della strumentazione di analisi | |
In Taratura Le misurazioni non sono significative in quanto durante il periodo le apparecchiature di misura hanno eseguito i cicli di taratura ovvero di verifica di corretto funzionamento. | |
Impianto non in Produzione Nel periodo di osservazione (giorno o mese) l'impianto controllato non era in produzione | |
Non Applicabile Nel periodo di osservazione (giorno o mese) l'impianto controllato ha superato lo stato di minimo tecnico per un tempo inferiore al mimimo richiesto pari a 6 ore per la media giornaliera e 144 ore per la media mensile, quindi il valore medio calcolato non è significativo. L'impianto controllato, per quanto concerne la media aggregata, è da considerare fermo | |
Non Disponibile Le informazioni per la grandezza non sono disponibili a causa di problemi tecnici del sistema di misurazione o memorizzazione. | |
Fuori Scansione Le informazioni non sono disponibili per fuori servizio delle apparecchiature di misurazione. | |
Superamento soglia normativa Il valore medio giornaliero misurato è superiore al rispettivo valore limite di emissione. |
Buzzi Unicem - Monselice - 853-0360-19
PF Sistemi s.r.l. Milano